Baltimore County |
Zoning Regulations |
Article 4. SPECIAL REGULATIONS |
Section 405. Fuel Service Stations |
§ 405.4. Standards.
A.
Site development.
1.
Site dimensions. The area of any fuel service station site shall be no less than 15,000 square feet or 1,500 times the number of fuel service spaces (as defined in Section 101), whichever is greater. If any use permitted under Section 405.4.D or 405.4.E is added to the fuel service station, the area of the site shall be increased in accordance with the provisions of those sections.
2.
Setbacks.
a.
No main structure of a service station shall be set back less than 35 feet from any street right-of-way; no fuel pump shall be set back less than 25 feet from any street right-of-way; no canopy shall be set back less than 15 feet from any street right-of-way.
b.
Except at the required access driveways, a landscape transition area shall be provided along the entire perimeter of fuel service stations. Such area shall have a minimum width of ten feet if the fuel service station abuts a public right-of-way, and six feet in all side and rear yards abutting nonresidentially zoned land, except that service stations located within 50 feet of any residentially zoned property (other than a residential zone line in a public right-of-way) shall provide a buffer measuring no less than 15 feet from that property line.
c.
The landscape transition area shall be vegetated and screened in accordance with the Landscape Manual requirements for automotive uses.
d.
Other setbacks shall be as required by these regulations.
3.
Access, internal circulation and vehicle reservoir capacity.
a.
The number and location of access driveways shall be determined by the hearing officer or Zoning Commissioner based upon the recommendations of the Director of Public Works and the Department of Planning.
[Bill No. 55-2011]
b.
All internal paved areas of a fuel service station site used for parking, driveway, aisles and stacking purposes shall comply with Section 409 and shall be laid out to preclude vehicles waiting on the street or blocking the right-of-way before gaining entrance.
c.
In addition to the fuel service space, at least one stacking space shall be provided:
(1)
For each pump island side, at pump islands that contain multiproduct dispensers (MPD) and where a bypass lane serves each MPD;
(2)
For each MPD in cases where there is no bypass lane or where a convenience store is located on the same lot; or
(3)
For each pump, if the pump dispenses a single fuel type.
d.
Parking spaces on the site of any fuel service station shall be provided as follows:
(1)
One space per employee on the largest shift.
(2)
Three spaces per 1,000 square feet of gross floor area for a convenience store up to 1,500 square feet. (Convenience stores larger than 1,500 square feet shall be subject to the parking requirements for retail uses in accordance with Section 409, including the first 1,500 square feet).
(3)
Three spaces per service bay, not counting service spaces in the bays.
(4)
One space per self-service air or vacuum cleaner unit.
(5)
One space per automatic teller machine.
B.
All fuel service stations shall provide a rest room facility, water and compressed air for customers.
C.
Appearance.
1.
General design.
a.
Any structure on the site that is converted to an ancillary use or to a use in combination with a fuel service station must be upgraded to create a unifying architectural theme with other structures on the site.
b.
The rear and sides of buildings on lots abutting residentially zoned properties shall be finished with materials that in texture and color resemble the front of the building. The type of facade treatment shall be indicated on the site plan or an accompanying elevation drawing and is subject to review by the Director of Planning.
c.
Except for the temporary outdoor sale of items permitted under Section 230.1.A.9, the outside display of merchandise is permitted only under the canopy, or if there is no canopy, on or between the pump island or in an area immediately adjacent to the cashier's kiosk. Such goods may not block access drives, stacking spaces or interfere with the site's circulation pattern.
d.
If the fuel service station is located within 50 feet of a residentially zoned property, lighting standards on site may not exceed a height of 18 feet and shall be directed away from any residentially zoned properties.
e.
To increase compatibility with surrounding buildings or to enhance the attractiveness of the site of fuel service stations for which a special exception is required, the Zoning Commissioner may specify additional requirements, including:
(1)
Changes in building or site plan design;
(2)
Restrictions on hours of operations; or
(3)
Other requirements deemed necessary for compliance with this section.
2.
Signs. Signs are permitted, subject to Section 450.
[Bill No. 89-1997]
3.
Maintenance. At all times, the premises shall be maintained in a clean and orderly condition. All landscaped areas shall be irrigated as needed and dead plants replaced. The responsibility for compliance with these provisions lies with all parties that individually or collectively have a lease or ownership interest in the fuel service station.
D.
Ancillary uses. The uses listed below, only, are permitted by right in conjunction with any fuel service station. The minimum area of the site as determined under Section 405.4.A.1 shall be increased each ancillary use by at least the number of square feet indicated below, which includes land for required parking and stacking spaces:
1.
Minor vehicle repair or diagnostic services to vehicles, except those which are unlicensed or which have a State Motor Vehicle Administration transporter or a dealer license. Additional site area of 1,300 feet per service bay shall be provided.
a.
Type of service and repairs include but are not limited to the sale and installation of mufflers, small auto parts and accessories and shall remain accessory to the fuel service station operation.
b.
All service and repairs shall take place within completely enclosed buildings.
c.
The combined area for sales, display and customer waiting room may not exceed 500 square feet.
d.
Storage of tow trucks, damaged or disabled vehicles or parts is subject to Section 405A.
2.
Convenience store, or a combination of a convenience store and carry-out restaurant, with a gross floor area of up to 6,000 square feet inclusive of accessory storage. An additional site area of four times the square footage of the gross floor area shall be provided.
[Bill No. 87-2016]
3.
Automatic teller machine, but no drive-through facilities. Additional site area of 1,000 square feet for each device shall be provided.
4.
Self-service vacuum stations. All such stations shall be located at least 30 feet from a residentially zoned property. No additional site area is required.
5.
Temporary outdoor sale of Christmas trees, firewood, cut flowers or live plants as limited by Section 230.1.A.9.
6.
The sale of cigarettes, candy, drinks, snacks and similar items from vending machines or the cashier's kiosk. No additional site area is required if vending machines do not exceed a total of five machines, otherwise the area shall be considered a convenience store.
7.
The retail sale of automotive service items such as motor oil, antifreeze or allied products. No additional site area is required.
E.
Uses in combination with fuel service stations. The minimum area of the site as determined by Section 405.4.A.1 shall be increased for each use in combination with a fuel service station by at least the number of square feet indicated below:
Type of Use
Integral
Planned
DevelopmentIndividual
Site(SE = Special Exception and P = Permitted by Right)
1. Convenience store, or a combination of a convenience store and carry-out restaurant, with a gross floor area larger than 6,000 square feet inclusive of accessory storage. Additional site area of four times the square footage of the gross floor area must be provided. [Bill No. 87-2016] SE SE 2. Roll-over car wash. No specific additional site area required, provided that the stacking, parking and buffer requirements of Section 419 are met. P SE 3. Full service car wash. No specific additional site area required, provided that the stacking, parking and buffer requirements of Section 419 are met. [Bill No. 53-2018 ] SE, except P if in Planned Drive-In cluster SE 4. Service garages providing services other than those listed in Section 405.4.D, subject to the provisions of Section 405.4.C.1.a through 1.e. SE SE 5. Automobile rental, with a maximum stock of 12 cars. Additional site area of 4,000 square feet must be provided. SE SE 6. Trailer rental, for trailers not exceeding ¾ ton chassis weight, with a maximum stock of 20 trailers. Additional site area of 5,000 square feet must be provided. SE SE 7. Light-truck rental, including rental of trucks equipped with campers, for trucks not exceeding 1½ tons' capacity, with a maximum stock of eight trucks. Additional site area of 4,000 square feet must be provided. SE SE 8. Parking of not more than six school buses. Additional site area of 2,600 square feet must be provided. SE SE 9. Self-service car washes. No additional site area required, provided that the stacking, parking and buffer requirements of Section 419 are met. SE Not Permitted 10. Restaurant, including fast food, fast food drive-through only, and carry-out restaurants. Additional site area of six times the gross square footage of the restaurant must be provided. SE SE